Red Cell Distribution Width as a Diagnostic Marker in Neonatal Sepsis: A Prospective Cross-Sectional Study at a Tertiary Care Hospital in Northeast India
M. Swathi Patil, Veeranna S Chikkamath, Anowar Hussain
Author(s)Abstract
Background: Neonatal sepsis remains a major cause of neonatal morbidity and mortality, particularly in resource-constrained settings. The nonspecific clinical presentation and limitations of conventional diagnostic tests complicate early diagnosis. Red cell distribution width (RDW), routinely reported in a complete blood count, may serve as an adjunctive marker of systemic inflammation. This study evaluated the diagnostic utility of RDW in neonates investigated for suspected sepsis. The objective is to compare RDW values between sepsis-screen-positive and negative neonates, determine the proportion of screen-positive neonates with elevated RDW, assess associations between RDW and conventional sepsis-screening parameters, and compare RDW and sepsis-screen performance against microbiological culture results. The study also evaluated RDW diagnostic accuracy using receiver operating characteristic (ROC) analysis. Material and Methods: A prospective cross-sectional study was conducted in the Neonatal Intensive Care Unit of Silchar Medical College and Hospital, Assam, India, from October 2024 to September 2025. A total of 172 neonates with suspected sepsis or associated risk factors were enrolled using consecutive sampling. RDW and conventional sepsis-screening parameters, including total leukocyte count, absolute neutrophil count, immature-to-total neutrophil ratio, C-reactive protein (CRP), and micro-erythrocyte sedimentation rate, were assessed. Blood culture was used as the primary microbiological reference standard. Urine culture and cerebrospinal fluid (CSF) analysis and culture were recorded as secondary findings when clinically indicated. RDW was compared between sepsis-screen groups and evaluated against blood culture results. ROC and regression analyses were performed to assess diagnostic performance and factors associated with sepsis. Results: Of the 172 neonates, 90 (52.3%) were classified in the sepsis group and 82 (47.7%) in the non-sepsis group. Mean RDW was higher among neonates with sepsis than among those without sepsis (17.8 ± 2.0% versus 15.2 ± 1.2%). At an RDW cutoff of 17.5%, the reported sensitivity was 80%, specificity 82%, positive predictive value 81%, negative predictive value 81%, and overall accuracy 81%. The reported area under the ROC curve was 0.85. RDW correlated positively with CRP (r = 0.42, p = 0.003). Conclusion: RDW demonstrated promising diagnostic discrimination in this hospital-based cohort and may complement conventional assessment of neonatal sepsis. Further multicentric studies using clearly defined reference standards are needed to validate its diagnostic performance and independent clinical value.
Keywords: Neonatal sepsis, red cell distribution width, sepsis screen, C-reactive protein, blood culture, newborn.