Correlation of Magnetic Resonance Imaging and Arthroscopic Findings in Meniscal Tears at a Tertiary Healthcare Centre

Ankit Thora, Harshwardhan Dawar, Hardik Sanghvi, Deepak Mantri, Laxman Banodha
Author(s)
1Assistant Professor, Department of Orthopaedics MGM medical College, Indore, Madhya Pradesh, India. 2Surgical Resident, Department of Orthopaedics MGM medical college, Indore, Madhya Pradesh, India. 3Associate Professor, Department of Orthopaedics MGM Medical College, Indore, Madhya Pradesh, India

Abstract

Background: Meniscal tears are common causes of pain, locking and functional limitation of the knee following trauma. Magnetic resonance imaging (MRI) is commonly used for non-invasive assessment. Arthroscopy allows direct visualisation and remains the reference standard for diagnosis and treatment. The objective is to evaluate the relationship between MRI and arthroscopic findings of meniscal tears and to assess the limitations of both diagnostic tools in a tertiary healthcare centre. Material and Methods: This prospective observational study included 46 patients with suspected traumatic meniscal injury. All patients underwent MRI followed by knee arthroscopy. Medial and lateral menisci were evaluated separately giving 92 meniscal assessments. MRI findings were compared with arthroscopic findings. Sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy were calculated. Agreement was assessed using Cohen's kappa coefficient and McNemar's test. Results: The mean age was 36.74 ± 10.58 years and 65.2% of patients were males. MRI detected medial meniscal tears in 54.3% while arthroscopy confirmed tears in 52.2%. Lateral meniscal tears were detected in 10.9% on MRI and 8.7% on arthroscopy. Overall, there were 26 true-positive, 60 true-negative, four false-positive and two false-negative findings. The combined sensitivity was 92.86% and specificity was 93.75%. Positive predictive value was 86.67% and negative predictive value was 96.77%. Overall diagnostic accuracy was 93.48%. Cohen's kappa was 0.849, indicating almost perfect agreement. McNemar's test showed no significant difference between MRI and arthroscopy positivity rates (p=0.683). Conclusion: MRI showed high diagnostic accuracy and good agreement with arthroscopy for meniscal tears. It is a useful non-invasive investigation for preoperative assessment. Arthroscopy remains important for definitive diagnosis and treatment when clinical and MRI findings are inconclusive or discordant.

Keywords: Arthroscopy, diagnostic accuracy, knee injury, magnetic resonance imaging, medial meniscus, meniscal tear, lateral meniscus.

Outline